Free Shipping Threshold: Only $50!
Shopping Cart
DKG-117 72x72mm Generator Control Panel with Synchroscope & Check Sync Relay - Industrial Power Generator Monitoring System for Backup Power & Grid Synchronization
DKG-117 72x72mm Generator Control Panel with Synchroscope & Check Sync Relay - Industrial Power Generator Monitoring System for Backup Power & Grid Synchronization

DKG-117 72x72mm Generator Control Panel with Synchroscope & Check Sync Relay - Industrial Power Generator Monitoring System for Backup Power & Grid Synchronization

$84.7 $154 -45% OFF

Free shipping on all orders over $50

7-15 days international

23 people viewing this product right now!

30-day free returns

Secure checkout

60382330

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

WE DO NOT SHIP THIS PRODUCT TO USA AND CANADAThe DKG-117 is a microprocessor controlled synchroscope with programmable synch check relay IN A DIN72 front panel mounted package. It monitors the voltage and frequency of 2 independent power networks as well as the instantenous phase angle between them. The measured parameters are displayed on the 3 digit digital display. The 24 led circular synchroscope displays the phase angle between 2 networks. The synchroscope display is only activated if both network voltages are within the set limits. The DKG-117 is mainly used in manual genset synchronization applications for synchronization checking between a genset and the genset busbar or between the genset busbar and the mains. The synchronization checking is enabled either via the SYNCH CHECK ENABLE signal input or by depressing the front panel SYNCH pushbutton. The synchronization checking consists of the verification of below conditions during 4 consecutive busbar cycles: -the busbar voltage between set limits -genset phase voltage between set limits - busbar-genset frequency difference below the set limit -busbar-genset voltage difference below the set limit -busbar-genset phase angle below the set limit If all above conditions are satisfied for 4 consecutive busbar cycles then the CHECK SYNCH relay will be immediately energized. If the busbar is not powered up, the synch checking may be overridden with the DEAD BUS ENABLE signal input. The SYNCH CHECK relay is deactivated either by removing the SYNCH CHECK ENABLE signal or by depressing the front panel SYNCH pushbutton. The DKG-117 provides a comprehensive set of digitally adjustable threshold levels and timers. All programs are modified via front panel pushbuttons, and do not require an external unit. The MENU pushbutton allows the digital display to navigate between various measured parameters.

Features

    WE DO NOT SELL THIS PRODUCT FOR USAGE IN USA AND CANADA

Reviews

******
- Verified Buyer
Worked out well.

We value your privacy

We use cookies and other technologies to personalize your experience, perform marketing, and collect analytics. Learn more in our Privacy Policy.

Top